Originlab originpro 8.6 sr2 free -

Looking for:

- Download OriginLab OriginPro (Portable).exe |  













































   

 

Originlab originpro 8.6 sr2 free -



  Origin has effective tools for computational requirements, including bend suitable, data, top analysis and sign processing. For better. Thank you for the free Origin software, which is very useful tool for data analysis and presentation. Being a researcher I need. Origin pro sr b97 x86 x64 , eng crack. free download from 年7月14日Download OriginLab OriginPro v8 0 SR2 MULTiLANGUAGE.  


Originlab originpro 8.6 sr2 free.3.2 System Variable List



 

It specifies the maximum number of graph layers to do merging. Any graph containing number of layers larger than GLL will not be shown in the Merge Graph window and thus cannot be merged. Edit: Copy Page normally copies an Origin graph object to the Clipboard. Determines whether to follow wks. Note : Introduced in 9. It controls the font size for the control labels when you are using the generic dyna control GetNBox, DynaControl or DynaBox to build a dialog.

It accepts the values in percent of internal value, the default value is It controls the gap between horizontal radio controls when you are using the generic dyna control GetNBox, DynaControl or DynaBox to build a dialog. It controls vertical gap between each control when you are using the generic dyna control GetNBox, DynaControl or DynaBox to build a dialog. Controls click selection behavior on data plots. Prior to Origin , when working with independent ungrouped plots, you clicked once on a plot to select the entire plot.

Pausing and clicking a second time selected an individual data point. When working with dependent plots grouped , you clicked once on a plot to select the group. Pausing and clicking a second time selected a single plot. Pausing and clicking a third time selected an individual point. It specifies default plot type. It specifies the factor to make automatic bin size estimate before the plotting of histogram. It is used to force the number of bins to HBM in regardless of what bin size might become before the plotting of histogram.

It is used to specify the number of bins and allow rounding before the plotting of histogram. It is used to specify the bin size before the plotting of histogram. It controls whether to allow dragging and dropping file to HTML dialog to open it. It is used to decide Smart Hint window position. This system variable controls whether the old or the new import tool is used. It is useful when the import file has more than one custom format and file size is small.

Note that it has no effect if the file is large and multi-thread is used, so this system variable will be usful only for smaller files. It determines the number of threads to use when import. It will be auto detected by logical processors. Set IAMT to 0 or 1 to disable multi-threading. From Origin , we support excluding file extension when appending file name to Comment. It controls whether to enable interpolation for bitmap drawing. It is used to specify how to show the plot labels such as axis label when the parameter substituted isn't found.

Does not apply to images inserted as layer background. Support import of Unicode fullwidth forms. This system variable is NOT Persistent.

See this FAQ on permanently changing the value of a system variable. To edit connected data after import see FAQHow to allow changing data when data connector is used?

All sheets in the new Excel file replace existing data or not when using "Import Replace Existing" mode to import multi-sheet Excel file. It specifies the number of columns for AutoSize column width when import file. When this system variable was introduced there was only a single Import Mode for all selected files. Support was later added so that during multi-file import, you could treat the first file and all subsequent files differently e.

For the purposes of this system variable, "import mode" refers to either 1st File or Multi-File settings. Toggle between different methods when calculates Kernel Density plot. When number of point of distribution curve is more than KDM1D, we will use new algorithm to speed up.

The threshold of number of points to toggle multi-threads for Kernel Density calculation. If the number of plotting data points is more than KDT, multi-threads will be called. It is used to control the shape of line ends for 3d openGL. It is used to toggle between sharp arrow and round-head arrow. It controls the line end cap for plots.

It controls double-clicking on the graph legend will open the Properties dialog or enter the in-place edit mode. Whether to auto-load "Linked File" image inserted into a Graph window. You can set the image as "linked" by right clicking inside the Image window and check Linked File menu. Whether to allow linked images in a Graph window to be auto-updated when the image file is changed.

The image is inserted into a Graph window by menu Insert: Image from File. You can set the inserted image as "linked" by double-clicking the image to open it in a separated window, and then right clicking on the image to check Linked File menu. It controls whether graphs in Layout Page are selectable or not, i. It controls whether use numeric comparison when running Lookup function. Lookup function's 1st and 2nd argument are string type.

It is used to specify the critical overlap percentage between data range and axes range beyond which drag-and-drop operation will trigger rescale action and check the Rescale on Apply checkbox on Layer Contents dialog box. Whether to show fill area pattern entry in the legend for area and fill under curve graph. Max number of legend entries to show in Browser Graph. It is used to specify the critical outside layer area in percentage for triggering rescale action upon using NLSF to add data.

Turn on debug log file. Logging can be automatically disabled after multiple sessions. It defines the maximum number of points we use to draw a single line segment in polyline drawing. Note: LP actually defines the resolution of polyline drawing. It controls whether to turn on or off the use of LP for 3D plot. When import data by Data Connector, this system variable determines whether to protect the column labels from editing. It specifies the maximum number of points used to draw a single line segment for drawing semi-transparent line plot.

It is used to control how the step line connection and fill area behave in the polar coordinate. It is used to estimate temporary series element size in mixed datasets for saving in percentage.

Controls how two semicolons in a line of script e. It specifies the default line width when create data plots. It is used to specify the color for Missing value in image view and in thumbnails for Matrix image. It specifies the critical percentage of cells that have missing values over which it will trigger missing values to be set as mask. It is used to specify the maximum of columns variables to decide whether auto import the columns variables without opening the Data Connector Browser.

It is used to specify the maximum columns if the variables are of same length to use workbook. It specifies the minimum column gap between legend entry columns when dragging legend entries into multiple columns for 2D graph in percentage of font height. It controls the minimum columns from Semicolon separator to skip Comma as separator. Basically if at least 4 columns detected using semicolon, then no longer check for Comma as separator.

But in some case, for example, comma separated into 6 columns while semicolon only 5, Origin will consider comma as a better separator then semicolon. To disable this change, user can set this system variable to a big number like It determines the maximum width for column Long Name to resize. It specifies the maximum column gap between legend entry columns when dragging legend entries into multiple columns for 2D graph in percentage of font height.

Setting is remembered between sessions. It specifies the size of a data point upon using Move Data Points to move data. It controls whether run mask event on the active layer.

It determines the number of nodes when the tree is created for browser purposes in Matlab Connector. It represents the pixels mouse moved in 0. Controls the time during which the newly created window of propert type will be added automatically. It specifies the critical time in seconds beyond which current collapsible context menu will auto expand to full menu without hovering over the double down-arrow icon on the collapsible menu bottom. It controls whether to force the size of the pages in the multipage PDF file made of graphs to be the union of the sizes of all the graphs, when export multiple graphs to a PDF file.

It controls whether to set all the margins to 0 both left-right and top-bottom , when export multiple graphs to a PDF file. It specifies the critical data label number that will trigger OpenGL render to use mechanism other than bitmap rendering to render the data labels in order to reduce bitmaps. It controls how often a menu item is used in order to be auto added to short list of collapsible menu.

Threshold number of colors to determine whether the imported palette is saved as a color list. Maximum XY re-sample boundary size.

Once exceeded, TCSM is set to 0 to automatically roll back to pre behavior. It controls whether to enable recently-used menu items and loading theme menu items. It specifies the default list size of most recently used books where the list corresponds to list in File:Recent Books. It specifies the default list size of most recently used exports where the list corresponds to list in File:Recent Exports.

It specifies the default list size of most recently used graphs where the list corresponds to list in File:Recent Graphs. It specifies the default list size of most recently used imports where the list corresponds to list in File:Recent Imports. Controls the maximum number of most recently used projects listed under File:Recent Projects.

Note the following limitation: if you increase MRUP to a value larger than 15, then add files to the projects' MRU files list and exit, the list will be saved correctly. If you then restart Origin, you must increase MRUP above the default of 15 before you show the menu with the list for the first time; otherwise all the entries beyond the 15th will be lost.

It controls when color map will save in matrix objct: 0: only during SetPalette new behavior 1: OnModify original behavior. It represent the maximum number for Total points increase factor during triangulation. Default is 0, means no limit. Set to, like, , which will allow the project to load and draw without getting stuck. It controls the map matching condition for Insert Map feature.

Set to 0 will disable minimum size requirement. Default 30 means layer range need to be at least 0. It is used to specify the maximum series number of box plot that can be plotted. It controls the threshold number of matrices, larger than which will show the thumbnail area using slider in the matrix window. Speed of mini toolbar fade-out as user mouses away from toolbar. Distance from hot spot click point on graph to mini toolbar popup.

It specifies the Time Stamp gap in seconds when dumping message to Message Log window. Multithreading has been implemented for line profile on Image Stack. For multithreading to be used the total number of points to be averaged over for all the points on the profile line, obtained as the product of the number of points to average over for a single point, multiplied by the total number of points on the profile line and multiplied by the number of frames, must be greater than or equal to the system variable MTPF.

It controls when uses the mouse position to show the mini toolbar. It controls the column with missing setup wks.

Disable the Reminder Message that shows when you select the Scale In tool dotool 1 and click on a graph without dragging out a rectangle. Grouped box charts Plot: Grouped Box Charts - Indexed rely on one or more columns of values Group Column s to define groups for statistical comparison.

When the selected data are to be grouped into more than NC groups, an attention message prompts the user to confirm that the calculation should proceed. In addition, graph previews are disabled. It is a percentage of the average time increment in the time variable of the NetCDF file. If you have problem about averaging irregular NetCDF file, it may be necessary to increase this percentage. It specifies the critical number of significant digits that will trigger double to string conversion.

It specifies the threshold modifier for Gaussian model that depicts how the noised data fits the Gaussian model. It specifies the maximum number of points a line plot has to have in order to trigger extreme range checking. It specifies the maximum number of points used for interpolated curve for extreme value checking. Note: when the maximum points has reached, it will no longer interpolate.

Maximum number of panels in trellis and cluster plot, over which dialog preview will be disable. It specifies the maximum number of page import info file nodes. It specifies the minimum number of lines to trigger progress bar to show for large data ASCII import. Speed up project loading and screen redraw times by controlling repaint of overlapped windows. By lowering the value of NPP, you can prevent repaint of a greater number of partially-covered windows e. The Python Console added Intellisense in Origin b.

Use this system variable to control whether to use the old Python Console no Intellisense or the new Console. From Origin , Smith chart handles complex with negative real better.

It controls whether replace the Script Window as Scintilla based. Notes window is Scintilla based from Origin The window now has a left margin by default. Set system variable NWM to 0 to turn off this margin. Note that different driver may give different speed. Default changed to 0 in Origin It controls whether to enable the improvement of OpenGL graph quality with transparency.

It controls whether allow multi-sampling anti-aliasing when only support 2 samples. It specifies the maximum pixel size of OpenGL window to do copy page using smart slice size. It controls the geometry slice size in 3D Vector Plot. The variable can be set to make 3d vector plot displays faster in high DPI or big monitor. It returns the locale of the resource which Origin is currently running. Control wheter to show plots in Object Manager panel for Browser Graph.

After changing the value, you will need to switch to other window to see the change. It specifies the gap between overlapped scatter data points in percentage of symbol width for offsetting overlapped data points.

It controls whether to use the darker axis lines when its color is set to Auto. It helps to fix crash caused by deleting preview graph. It decide whether to use relative references when copy and paste a cell formula. It specifies the threshold in KB to save preview images above which compression will take place to zip images. When set the distribution curve color of histogram to Auto , this system variable controls the auto color variations. The auto distribution curve color follows the bar Fill Color but is darker version by default.

If plot fill color is set to None or Auto , it follow border color. This system variable determines the darkness varying from the fill color in percentage. Darker when its value increases. It controls the behavior for finding Help topics when we click? It controls whether to disable put temp file into Recent File List when back project by LabTalk save command. By default, when Clip Data to Frame is on, any plot symbol or associated data label that lies on the layer frame, is drawn in full, to include any portion that lies outside the frame.

Whether to pop up the confirm message box asking window deletion multiple times when deleting multiple folders or windows. The message box pops up for every window deletion. From Origin , sub-folders will not be listed in the Project Explorer's bottom panel. You can set this system variable to 1 to go back to the old behavior. It controls whether needs to hold Ctrl key to see the previews image of Workbook, Graph windows in Project Explorer sub-panel. Maximum number of windows to show per folder when switching between Project Explorer PE folders.

Priority given to most-recently active windows. Notes windows are not affected. May improve system performance by limiting the number of windows redrawn each time the PE folder is opened. It controls the height of the comment tooltip in Project Explorer so as to control how many lines to show in tooltip. Need to refresh the window to take effect.

Notes: The above values are additive. When there are multiple windows, the active window is used as preview. Save the project file to see the change. When using "Fit until Converged" tool to fit peaks, the peak center handling is not dimension sensitive so that you may get the wrong peak direction at the end. To deal with this problem, this system variable is added to automatically fix peak center for 20 iterations. See FCI to change the number of iterations. This system variable determines the lightness varying from the border color in percentage.

Lighter when its value increases. When changing, it will update the display accordingly. It controls whether to support undo after modifying function plot in the Plot Details dialog. It determines how the pattern is assigned when a incremental pattern list is applied to color scal levels. It controls the maximum number of input data points to output baseline data to "info" Notes in Quick Peaks gadget's result.

It controls the maximum number of peaks to show base markers and integrated areas in the ROI box of Quick Peaks gadget. When you select a plot in Object Manager under a layer or group, the selection will be highlighted while the unselected ones will fade out. When you select a node or link in the Chord diagram, the selection will be highlighted while the unselected ones will fade out.

See PSFF for a general control. It controls the size change threshold to trigger the auto-rescaling of elements to fit the graph window size when change the graph page dimensions.

It controls whether to show tooltips of the source data when mouse hovers over a data plot. Controls display of data point tooltip when hovering on a data point. From Origin , copying from Word and then pasting into Origin graph will paste as text by default. If you want to paste Word content as Word object, use Paste Special menu. From Origin , copying Excel cells and then pasting into Origin graph will paste as text by default.

If you want to paste Excel cells as Excel object, use Paste Special menu. Determine whether to output Python print immediately for Enbedded Python. Whether to prevent using Python in Script Window. It controls the delicate transparency mode in contour graphs.

Determine the axis title substitution notation "? The "? It uses the first data plot by default. This system variable determines whether to skip the invisible plot. Threshold for considering a double value to be 0. Set it to 1. Controls seed value algorithm used by LT functions when seed is not specified to generate random numbers in Origin. This also controls behavior of GUI methods for generating random datasets.

The new algorithm incorporates the system tick count generated by the system timer to seed the random number functions. Font color of the connected sheet in the Data Navigator. Font color of the disconnected sheet in the Data Navigator.

Background color when you highlight or select a row in the Data Navigator. Enables or disables spreadsheet cell notation SCN in the workbook. Analysis X-Functions which will not be affected when bit is on: Split Worksheet: wsplit - output follows source book state. Bits are additive. See SCNI , below. Control whether to adjust column label width or height of the analysis result columns.

Whether to reset dialog position on new Origin session startup. It specifies maximum supported vector size that can go into report data without passing by reference. It specifies the column auto resize limit upon highlighting columns and double click the divider between columns to auto resize column width. It specifies the row auto resize limit upon highlighting rows and double click the divider between rows to auto resize column width. It controls the default choice for the 4 choices reminder message box: 0: no by default 1: yes by default, the same behavior in old version.

From Origin b, if you have multi-layer graph and layers are linked, clicking the Rescale button will rescale the axis ranges of all linked layers, no matter the axes are linked or not, or which layer are active.

The threashold of partial import resulted rows beyond which multi-threaded code is used. Otherwords, if the number of rows imported is less then RMT, single thread is used. Default is Black. It controls the maximum row height of the report sheet's label rows for autosize. It controls whether the graph object can be resized when Horizontal and Vertical Movement are disabled. Determines how the From and To axis scale values are calculated from dataset minimum and maximum values.

When an OPJ contains linked cell, the source data change will trigger auto update in the related graph and worksheet. However, search for linked data may heavily slow down speed. It controls whehter to correct short name with non English characters when open the OPJ file.

It specifies the regional selector sensitivity to the existing data marker in percentage of scatter symbol size. It controls whether to treat missing value as a special incomparable value or not. The threshold time in milliseconds determining whether a graph should redraw when it is uncovered.

Otherwise, NPP will decide whether the graph should redraw or not. Whether to activate plot by clicking to select that plot. Controls sorting behavior in left-panel of Layer Contents dialog box. When performing Statistics on Columns, preserves input column Format of a Group column in the output sheet e. Hide Short menus by default.

By default, SCN is turned on in new workbooks. Set Column Values should not set an operation lock when using input as output. It controls whether to keep formula as the user typed in the Set Values dialog or F x cell. It specifies whether to pop up the error message "Please close all open dialogs before closing Origin.

Determine whether to change the output column designation. Scientific exponent digits for tick label. Optional faster initial rendering of worksheets with large number of sparklines by saving images of sparklines depending on size of image in bytes. It specifies the Char symbol scaling factor in unit of default internal char symbol scaling factor When you perform Copy Columns to on filtered data, you can lock the worksheet filter in the output sheet.

It controls whether to set a column as categorical if it is mostly text and used as grouping column in an analysis tool or plotting. It specifies the number of steps for UV to construct the axis and grid lines for Smith Chart.

Note: the bigger the SI, the better the resolution of Smith chart would be. It is used to control whether non-English character is allowed for variable name. It specifies the gap between two smart labels in percentage of label height in order to avoid overlapping.

Whether to use cell value linking in Button Edit Mode. It controls whether to show the last data point in Speed Mode and Skip Points mode. The maximum number of files to show in Recent Files list of Start menu.

Note that books otpu, otp and graphs oggu, ogg are excluded, only recent projects opju, opj are listed in Recent Files. Origin File Exchange. Items per page: 15 25 50 Neural Network Regression by OriginLab.

Speedy Fit by OriginLab. Structural Equation Modeling by OriginLab. Empirical Mode Decomposition by OriginLab. Optimal Cluster Number by OriginLab. Peak Deconvolution by OriginLab. Hurst Exponent by OriginLab. Allan Variance by OriginLab. Neural Network Fitting by OriginLab. Detrended Correspondence Analysis by OriginLab.

Independent Component Analysis by OriginLab. Change Point Analysis by OriginLab. Radiometric Geochronology Analysis by OriginLab. Design of Experiments by OriginLab. Mann-Kendall Test by OriginLab. Version: b 9. Version: 9. DOE: Design an experiment, fit a model to experimental data, and find best factor settings that optimize responses. Perform Mann-Kendall test to determine whether input data has a monotonic upward or downward trend. Explore the relation between continuous or categorical independent variables and specified quantiles of a dependent variable.

OriginLab Corp. Origin File Exchange. Items per page: 15 25 50 Neural Network Regression by OriginLab. Speedy Fit by OriginLab. BioLogic Connector by OriginLab. Structural Equation Modeling by OriginLab. Empirical Mode Decomposition by OriginLab. Optimal Cluster Number by OriginLab. Venn Diagram by OriginLab. Tafel Extrapolation by OriginLab.

Plot Sub Matrix by OriginLab.

   

 

- Originlab originpro 8.6 sr2 free



   

System Variables are used in Origin to control various behaviors, generally at a much lower level than settings found in Preference: Options. There are several hundred system variables. A typical Origin user may need to set only a few of them based on their particular needs. Unless recommended by an FAQ or by technical support, there is usually no need for a user to check or set system variable. All system variables have a default value, and a set of supported values.

To change the value of a system variable, do the following:. F Note that if you wish to leave the entry in the table, and simply want to revert to default value, you can change the value in the second column to the default value for that variable. Of the severa LGl hundred system variables, a small number are of the Persistent type. These are marked as Persistent in the table below. All other system variables are non-Persistent. The difference does not matter if you set or reset the variable from the Set System Variables dialog as described above.

If the variable is non-Persistent, then the value assigned from script or command window will be valid only for the current session. For Persistent system variables, when the value is changed either from the dialog or from script, the new value is stored in the Windows Registry at:. The tables below list all available system variables in alphabetic order and are divided into sections by first letter.

AB is only applied to version earlier than 9. When you right-click on the sheet tab to select Add Graph as Sheet , the Graph Browser will open to let you select a graph window and add into the workbook as a sheet.

When you right-click on the sheet tab to select Add Graph as Sheet , the hunt dialog will pop up. You can click on the desired graph window to select it and click on Done button to add the graph as a new sheet. First, try to rotate tick labels from 0 to 45; if still overlapped, set the Rotate to 90; if still overlapped, hide some tick labels.

You will need to open Help: App Center to update them manually. It can be only seen when recalculation time is long enough. Note: when auto recalculation time is less than AUBT ms, then message box will not show up. When Origin is auto-updating, the updating progress will show in Message Log. Note: this system variable is updated in Origin SR1, adding values 2 and 3. Note: It is equivalent to System.

Debug object property. This system variable controls X-Functions: smooth , normalize , vnormalize , interp1 , interp1trace , and interp1xy. Note that the conversion from binary bit double-precision to decimal "full precision" may result in very small rounding discrepancies. See this FAQ for details. If you want to use the wks. In other situations, DIB is not copied. Note: CPGD was changed for b and Default is entries. Old behavior. For example Note: The "D" in D n must be uppercase.

DBO is introduced to improve the speed in this situation. Result tables in embedded graphs will maintain links to original source data when copied or cloned. Note: See system variable UCM. Note: this system variable only takes effect on new created Notes window.

Once a Notes window has been converted to render mode, changing DCEH value after that will not change the double-clicking switching mode for this Notes. Take both data and label rows into consideration when check if a column is empty or not. Only data section is checked and also disable merged label checking when consider column to be empty or not.

This is default behavior. This is Origin's behavior before version ETG is introduced later to implement all Apply editable box. In addition, for other bits 2, 4 to take effect, you must enable guessing. For example. If columns in a worksheet have different length, all cells after that column range will be considered empty. The old behavior.

Wipe out cell link, cell formula etc upon duplicating. You can still open it by File: New: Workbook. Note: grid lines density reduction towards center is controlled via system variable DPA. Refer to DRI for detailed explanation. The effect can be seen more clearly for large data plot.

This dependency is logarithmic. Use this "" system to maximize numeric precision. Note: it is used for data plot hit-test. For grouped data plot, a single hit on any data point will highlight DTB number of un-overlapped data points from all data plots within the group. Note: DTF can be regarded as the resolution of freehand drawing tool. The smaller DTF is, the smoother the freehand drawing would be. Note: when click to select a graphic object, there are some green square handles around the object which can be used to adjust the position and shape of the graphic object.

These green squares are the draw tool handles mentioned above. When DTN is negative, it will move in opposite direction to arrow key direction. Note: click free area refers to area within which single or double click will have no effects, such as to select, bring up dialog box.

Point of click defines the region within which Origin object can be clicked to select. Note: refer to DTO for the meaning of click free area. Since axis minor grid selection is no longer available, DTOG will not function as before. Since axis major grid selection is no longer available, DTOM will not function as before. Note: within the region defined by DTOS, single click will bring the data reader cursor to corresponding data point.

Note: This dynamically allocating new count can save space and improve efficiency where directly allocate a large number of counts could be redundant. DTR actually defines the resolution of ellipse object. DTS actually defines the resolution of curved arrow drawing.

Note: beyond the region mentioned above while still inside legend box, a single hit will select the border and along with text inside meanwhile displays green handles around the box.

The default color is Blue in transient state. The default value is an internal color code of RGB ,, You can use the color function to get this internal color code for the desired color. Note: for the legend of a plot, substitution level is 1. The Histogram Plot checkbox adds a scatter histogram to the plot. The Adjacent checkbox moves the scatter histogram to the side of the Box Chart 3.

Of the two Symbol Size drop-down lists: The first controls the size of the five 'features' located at the bottom of the dialog The second controls the size of the scatter histogram and uses its own relative sizing. See : ProjectEvents Script.

You don't need to set this system variable to troggle the speed up improvement. These controlling bits can be combined to produce cumulative effects. For example, if the input data range is from 1E05 to 1E If any of the method 1 or 2 fail, it will resort to the default i. OGS file, at the command line in the Script Window.

Note that each sheet in the book can have a different setting. Overrides individual sheet settings. Note: HBM is for number of bins that is not rounded so that it is the exact number of bins could be non-integers. Localized videos C, G, J will only be installed with Help files. Learning Center should preferentially play locally-installed file if it exists. For C, G, J check for localized file, then for locally-installed E file.

If localized file or locally-installed E file not found, go to video page on originlab. If no any user-defined filter, the system filter will be used. This is Origin's behavior before version b. This system variable is no longer used anymore, the drawing sequence now is replaced by the corresponding check box Grid on Top of Data and Data on Top of Axes respectively in Data Drawing Options panel under Display in Plot Details dialog box. Only the first sheet replace the existing data sheet.

The rest will be imported into new sheets.



Comments